In short: a free steam audit by Johar Engineering is a study of how your plant generates, distributes and uses steam. We find where steam and heat are being wasted, calculate what each loss costs you per year in rupees, and give you a savings report that ranks the fixes by saving and payback, so you know exactly where your money is going and how much you can get back.
~190 kg/hsteam lost through one passing drain valve on a 67 bar header
~31 kg/hlost through one failed-open steam trap at 10 bar
~₹6 lakha season from that one valve, even on bagasse steam at about ₹690 a tonne
Napier orifice formula, 3 mm effective opening, 180-day season. Your own figures will differ: try them in our steam loss calculator.
Where Your Steam Money Goes
Steam is usually one of the largest energy costs in a process plant, and most of the waste is invisible from the boiler house. Fuel is burned, steam is made, and a share of it never does useful work. The common losses are:
Passing valvesDrain, vent, bypass and blowdown valves that look shut but pass steam through a worn seat. Usually the biggest single loss, and the one nobody checks.
Excess boiler blowdownBlowing down more than the boiler water TDS needs throws away hot, treated water. Blowdown flash that is not recovered wastes usable low-pressure steam.
Steam leaksSmall leaks at flanges, glands, valve stems and joints run all day, every day. Individually they look minor; together they can add up to lakhs a year.
Failed and passing steam trapsA trap stuck open blows live steam into the condensate line. A blocked one waterlogs equipment and slows production. Both cost money quietly.
Bare and damaged insulationUninsulated pipes, valves, flanges and fittings lose heat continuously and turn steam into condensate before it reaches the process.
Condensate going to drainCondensate is hot, treated water. Every litre dumped has to be replaced with cold make-up water that must be treated and heated again.
Flash steam ventedWhen hot condensate drops in pressure, part of it flashes to steam. Vented to atmosphere, that heat is lost; recovered, it can feed a low-pressure user.
Poor steam utilizationAir in heat exchangers, waterlogged coils, steam used at a higher pressure than the process needs, and open bypasses all mean more steam for the same output.
Estimate Your Steam Loss Cost
Use our free steam loss calculator to work out your steam cost per tonne and what passing valves, failed traps, bare insulation, excess blowdown and lost condensate cost you each year. Enter only what you know: a few fields are required, and the rest use typical values that are clearly listed.
Open the steam loss calculator
What the Steam Audit Covers
We follow the steam from the boiler header to every point of use and back as condensate, looking for anything that wastes steam or heat:
- Passing valves: drain, vent, bypass, blowdown and PRDS valves checked for seat leakage with thermal imaging and ultrasound.
- Distribution losses: leaks, bare or damaged insulation, open bypasses, dead legs and poorly drained mains.
- Steam trap performance: traps that pass live steam, traps that hold back condensate, and traps unsuited to the duty.
- Condensate recovery: how much condensate comes back to the boiler, how much goes to drain, and what it would take to return more.
- Flash steam recovery: vented flash that could heat feed water or serve a low-pressure user.
- Steam utilization at the process: heat exchangers, juice heaters, evaporators, dryers and jacketed vessels, checking for air, waterlogging and steam supplied at a higher pressure than the process needs.
- Boiler blowdown: actual boiler water TDS against the permissible limit, and whether blowdown flash steam is recovered.
- Insulation: thermal survey of valves, flanges and pipe for bare, damaged and wet insulation.
What You Receive: a Savings Report
- Your steam cost per tonne, worked out from your fuel, GCV and boiler efficiency.
- An estimate of steam lost in kg per hour and tonnes per year, finding by finding.
- The annual cost of each loss in rupees, worked out from your own fuel cost and operating hours.
- A ranked list of savings opportunities, with the expected saving and simple payback for each.
- Quick wins you can do with your own team at little or no cost.
- Recommendations to improve steam utilization: condensate return, flash recovery, pressure matching and better heat transfer.
You get a number you can take to management: what the losses cost today and what fixing them is worth, based on your plant’s data rather than a generic percentage.
How the Free Steam Audit Works
1Book the auditFill in the form or message us on WhatsApp with your plant, location and fuel.
2Share basic dataFuel type and cost, steam generation, boiler pressure and operating hours, so we can put a rupee value on every loss.
3Plant surveyWhile the plant is running, we test valves and traps with ultrasonic and thermal instruments, from the boiler header to each user and back.
4Savings reportYou receive the findings with the annual cost of each loss and the savings and payback of each fix. What you do next is your decision.
Who Saves the Most
The bigger the steam bill and the longer the operating hours, the more an audit is worth. We work with plants in:
- Sugar and ethanol: boilers, juice heaters, evaporators, pans and distillery steam, where a season of losses adds up fast
- Captive power and cogeneration: steam mains, headers and turbine drains
- Chemical and process plants: reactors, jacketed vessels and heat exchangers
- Pharma, food processing, dairy, textile and other plants that use steam for heating, drying and sterilizing
We cover plants in Pune, Ahilyanagar (Ahmednagar) and Beed. For Jalna, Latur or Nanded see our Marathwada page and ask us about a visit.
Book Your Free Steam Audit
Free Steam Audit: Frequently Asked Questions
What is a steam audit?
A steam audit is a study of how your plant generates, distributes and uses steam. It finds where steam and heat are being wasted, works out what each loss costs you per year, and lists the changes that will cut that cost, ranked by saving and payback.
Is the steam audit really free?
Yes. The site visit and the savings report cost nothing and carry no obligation. You can act on the report with us, with another contractor or with your own maintenance team.
How much can we save?
It depends on your plant: steam pressure, operating hours, fuel cost and how much steam is being lost today. That is exactly what the audit measures. As an illustration, one passing drain valve on a 67 bar header can lose about 190 kg of steam an hour, which is close to Rs 6 lakh over a 180-day season even on bagasse steam at about Rs 690 a tonne. One failed-open trap at 10 bar loses about 31 kg an hour. Most plants have many such losses, so totals in lakhs are common. Your report gives the figure for your plant, from your own steam cost.
What does the audit look at?
Passing drain, vent and bypass valves, steam traps, steam leaks, bare or wet insulation on valves, flanges and pipe, boiler blowdown, flash steam and condensate return. In most plants, passing valves and failed traps are worth more than everything else combined, so that is where we spend most of the site time.
What do you need from us?
Fuel type, monthly consumption, delivered price and GCV; boiler capacity and actual steam generation; operating pressure and temperature; feedwater temperature; operating hours or season dates; and the latest boiler water and feedwater TDS results. Without these we cannot put a rupee figure on what we find. Line diagrams, a trap list and turbine data help but are not essential.
How long does it take?
A small plant can be covered in a day. A mid-size sugar mill or process plant usually takes about three days on site. We present the top findings to your team before we leave, and the written report follows. We confirm timings when we agree the date.
When should the audit be done?
While the plant is running. Steam traps and valve seats can only be tested with steam flowing. For sugar mills that means during the crushing season, so fixes can be planned and carried out in the off-season.
Is this a statutory energy audit?
No. This is a steam system survey focused on steam losses and their cost. A statutory energy audit under the Energy Conservation Act covers all energy streams and must be done by a BEE-certified energy auditor.
Do I have to buy anything?
No. Many of the savings an audit finds cost little or nothing to fix: closing open bypasses, repairing leaks, insulating bare pipe, returning condensate that is being drained. Where equipment is needed, the report says so, and buying it from us is entirely your choice.
Which areas do you cover?
Plants across Pune, Ahilyanagar (Ahmednagar) and Beed districts. If your plant is in Jalna, Latur, Nanded or elsewhere in Maharashtra, message us and we will tell you what is possible.
When Equipment Is Needed
Most savings come from fixing what is already installed. Where the report does recommend new equipment, such as steam traps, isolation valves or control valves, we can supply genuine KSB products as an authorized KSB dealer, including KSB ECOLINE steam traps. You are free to source elsewhere.